A centrifuge with a bowl which is 500 mm long and has an inside radius of 50.5 mm is to be used to separate crystals from a dilute aqueous mother liquor. The optimum speed of rotation for the centrifuge is 60,000 rpm, and the discharge weir is adjusted so that the depth of liquid at the bowl wall is 38.5 mm. The crystals are approximately spherical and none are smaller that 2 x 106 m in diameter. The maximum volumetric flow rate in m³/s of the mother liquor that can be processed by this centrifuge if all the crystals have to be removed is a. 0.054 b. 0.024 c. 0.154 d. none of these

Introduction to Chemical Engineering Thermodynamics
8th Edition
ISBN:9781259696527
Author:J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Publisher:J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Chapter1: Introduction
Section: Chapter Questions
Problem 1.1P
icon
Related questions
Question

please help me with these. 

8. A centrifuge with a bowl which is 500 mm long and has an inside radius of 50.5 mm is
to be used to separate crystals from a dilute aqueous mother liquor. The optimum
speed of rotation for the centrifuge is 60,000 rpm, and the discharge weir is adjusted so
that the depth of liquid at the bowl wall is 38.5 mm. The crystals are approximately
spherical and none are smaller that 2 x 10 m in diameter. The maximum volumetric
flow rate in m³/s of the mother liquor that can be processed by this centrifuge if all the
crystals have to be removed is
a. 0.054
b. 0.024
c. 0.154
d. none of these
Transcribed Image Text:8. A centrifuge with a bowl which is 500 mm long and has an inside radius of 50.5 mm is to be used to separate crystals from a dilute aqueous mother liquor. The optimum speed of rotation for the centrifuge is 60,000 rpm, and the discharge weir is adjusted so that the depth of liquid at the bowl wall is 38.5 mm. The crystals are approximately spherical and none are smaller that 2 x 10 m in diameter. The maximum volumetric flow rate in m³/s of the mother liquor that can be processed by this centrifuge if all the crystals have to be removed is a. 0.054 b. 0.024 c. 0.154 d. none of these
Expert Solution
steps

Step by step

Solved in 4 steps with 23 images

Blurred answer
Recommended textbooks for you
Introduction to Chemical Engineering Thermodynami…
Introduction to Chemical Engineering Thermodynami…
Chemical Engineering
ISBN:
9781259696527
Author:
J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Publisher:
McGraw-Hill Education
Elementary Principles of Chemical Processes, Bind…
Elementary Principles of Chemical Processes, Bind…
Chemical Engineering
ISBN:
9781118431221
Author:
Richard M. Felder, Ronald W. Rousseau, Lisa G. Bullard
Publisher:
WILEY
Elements of Chemical Reaction Engineering (5th Ed…
Elements of Chemical Reaction Engineering (5th Ed…
Chemical Engineering
ISBN:
9780133887518
Author:
H. Scott Fogler
Publisher:
Prentice Hall
Process Dynamics and Control, 4e
Process Dynamics and Control, 4e
Chemical Engineering
ISBN:
9781119285915
Author:
Seborg
Publisher:
WILEY
Industrial Plastics: Theory and Applications
Industrial Plastics: Theory and Applications
Chemical Engineering
ISBN:
9781285061238
Author:
Lokensgard, Erik
Publisher:
Delmar Cengage Learning
Unit Operations of Chemical Engineering
Unit Operations of Chemical Engineering
Chemical Engineering
ISBN:
9780072848236
Author:
Warren McCabe, Julian C. Smith, Peter Harriott
Publisher:
McGraw-Hill Companies, The