Q1/ Correct and incorrect and correct the error if found. 1- It is not possible to increase the speed of a shunt DC motor above rated using flux field control 2-The main disadvantage of potential divider control method of shunt DC motor, the speed up to zero is not possible. 3-The armature voltage of series DC generator is not affected by field current. 4- To solve the armature reaction Problem in large machines, this can be achieved by increasing the brush width 5-In shunt d-e generator the field winding will be constructed from high number of turns and high cross-sectional area of wire. 6-The inter pole winding is connected in parallel to field winding. 7-The produced sparks at the brushes of a de machine is due to friction losses. 8-Series DC motors are used for low torque applications. 9-In series DC generator, Increasing the load current will decrease the magnitude of the generated voltage. 10-The compensation windings are place at the pole face and used to mitigate the effect of the armature reaction.

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
100%
Electrical engineering subject of electrical machines/ I need a correct and accurate solution
Q1/ Correct and incorrect and correct the error if found.
1- It is not possible to increase the speed of a shunt DC motor above rated using flux field control
2-The main disadvantage of potential divider control method of shunt DC motor, the speed up to zero is not possible.
3-The armature voltage of series DC generator is not affected by field current.
4- To solve the armature reaction Problem in large machines, this can be achieved by increasing the brush width
5-In shunt d-e generator the field winding will be constructed from high number of turns and high cross-sectional
area of wire.
6-The inter pole winding is connected in parallel to field winding.
7-The produced sparks at the brushes of a de machine is due to friction losses.
8-Series DC motors are used for low torque applications.
9- In series DC generator, Increasing the load current will decrease the magnitude of the generated voltage.
10-The compensation windings are place at the pole face and used to mitigate the effect of the armature
reaction.
Transcribed Image Text:Q1/ Correct and incorrect and correct the error if found. 1- It is not possible to increase the speed of a shunt DC motor above rated using flux field control 2-The main disadvantage of potential divider control method of shunt DC motor, the speed up to zero is not possible. 3-The armature voltage of series DC generator is not affected by field current. 4- To solve the armature reaction Problem in large machines, this can be achieved by increasing the brush width 5-In shunt d-e generator the field winding will be constructed from high number of turns and high cross-sectional area of wire. 6-The inter pole winding is connected in parallel to field winding. 7-The produced sparks at the brushes of a de machine is due to friction losses. 8-Series DC motors are used for low torque applications. 9- In series DC generator, Increasing the load current will decrease the magnitude of the generated voltage. 10-The compensation windings are place at the pole face and used to mitigate the effect of the armature reaction.
Expert Solution
steps

Step by step

Solved in 3 steps with 1 images

Blurred answer
Knowledge Booster
Speed control of motor
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,