Q4/ Find the values of incremental fuel costs using LaGrangian multipliers for the two-unit system supplying 400 MW at the first hour and 401 MW at the next hour of the following fuel equations: F1=0.016(P1)2 + 2.187(P1) + 120.312 S/hr F2=0.019(P2)2 + 2.407(P2) +74.074 $/hr

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter6: Power Flows
Section: Chapter Questions
Problem 6.45P
icon
Related questions
icon
Concept explainers
Question
Q4/ Find the values of incremental fuel costs using LaGrangian multipliers for the two-unit
system supplying 400 MW at the first hour and 401 MW at the next hour of the following fuel
equations:
F1=0.016(P1)2 + 2.187(P1) + 120.312 S/hr
F2=0.019(P2)2 + 2.407(P2) +74.074 $/hr
Transcribed Image Text:Q4/ Find the values of incremental fuel costs using LaGrangian multipliers for the two-unit system supplying 400 MW at the first hour and 401 MW at the next hour of the following fuel equations: F1=0.016(P1)2 + 2.187(P1) + 120.312 S/hr F2=0.019(P2)2 + 2.407(P2) +74.074 $/hr
Expert Solution
steps

Step by step

Solved in 2 steps with 3 images

Blurred answer
Knowledge Booster
Load flow analysis
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning