A lightning strikes a 30-m unshielded over-head transmission line tower Which has the following parameters Surge impedance of the tower= 100ohms Surge impedance of lightning channel at tower top =500ohms Tower-footing resistance=10ohms Tower height =30 m Cross-arm height=27m The lightning strike current is assumed to be a constant 30 kA for a duration of 20 µs. The traveling wave propagation speed in the tower is 1.2* 10­­8 m/s. a)draw the voltage lattice diagram with proper labels of the time b) ignoring the phase voltage, determine the insulator voltage after 2µs. c) The insulator voltage approaches a constant value after 2 µs. If the basic impulse insulation level (BlL) of the insulator for phase conductor is 150 kV, evaluate the condition of the insulator and conclude the type of power quality problem that will occur for an end-user facility connected to the transmission line. Assume that the surge arresters and circuit breakers at the end-User facility are working properly.

Delmar's Standard Textbook Of Electricity
7th Edition
ISBN:9781337900348
Author:Stephen L. Herman
Publisher:Stephen L. Herman
Chapter20: Capacitance In Ac Circuits
Section: Chapter Questions
Problem 3RQ: How many degrees are the current and voltage out of phase in a pure capacitive circuit?
icon
Related questions
Question
  1. A lightning strikes a 30-m unshielded over-head transmission line tower Which has the following parameters

Surge impedance of the tower= 100ohms

Surge impedance of lightning channel at tower top =500ohms

Tower-footing resistance=10ohms

Tower height =30 m

Cross-arm height=27m

The lightning strike current is assumed to be a constant 30 kA for a duration of 20 µs. The traveling wave propagation speed in the tower is 1.2* 10­­8 m/s.

a)draw the voltage lattice diagram with proper labels of the time

b) ignoring the phase voltage, determine the insulator voltage after 2µs.

c) The insulator voltage approaches a constant value after 2 µs. If the basic impulse insulation level (BlL) of the insulator for phase conductor is 150 kV, evaluate the condition of the insulator and conclude the type of power quality problem that will occur for an end-user facility connected to the transmission line. Assume that the surge arresters and circuit breakers at the end-User facility are working properly.

Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
Compensation Techniques in Transmission Line
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning