Refrigeration and Air Conditioning Technology (MindTap Course List)
Refrigeration and Air Conditioning Technology (MindTap Course List)
8th Edition
ISBN: 9781305578296
Author: John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher: Cengage Learning
bartleby

Videos

Textbook Question
Book Icon
Chapter 50, Problem 11RQ

The most efficient way to establish the best possible economizer position is to measure
A. the dry-bulb temperature of the return and outside airstreams.
B. the dry-bulb temperature of the return air and the enthalpy of the outside air.
C. the enthalpy of the return air and the dry-bulb temperature of the outside air.
D. the enthalpy of both the return air and the outside air.

Blurred answer
Students have asked these similar questions
Pick the right combination of True Statements. 1. As the by-pass factor (BPF) of the cooling coil increases, temperature difference between air at the outlet of the coil and coil ADP decreases. 2. As the by-pass factor (BPF) of the cooling coil increases, temperature difference between air at the outlet of the coil and coil ADP increases. 3. During cooling and humidification process, the enthalpy of air may increase, decrease or remain constant depending upon the temperature of the wet surface. 4. During sensible cooling of air, dry bulb temperature decreases but wet bulb temperature remains constant 5. The sensible heat factor for a sensible heating process is 1.0
Recirculated air from the indoor space is 7,500 cfm (75 degrees F dry bulb, 50% RH). Ventilation air from outdoors is 2,500 cfm (95 degrees F dry bulb, 76 degrees F wet bulb). Leaving air off the cooling coil is 10,000 cfm (55 degrees F dry bulb, 90% RH). What is the wet bulb temperature of the indoor air that is being recirculated? Group of answer choices 61.5 degrees 63.5 degrees 62.5 degrees 61 degrees
A domestic refrigerator sits in a kitchen, switched on, with the refrigerator door wide open. The kitchen itself is well insulated and it can be assumed no heat can escape or enter the kitchen from the outside. Which of the following is the most accurate statement. а. The temperature in the kitchen will stay the same. O b. The temperature in the kitchen could go up or down depending on the mechanical efficiency of the compressor. O c. The temperature in the kitchen will go down very slightly. d. The temperature in the kitchen could go up or down, depending on the Coefficient of Performance (COP) of the refrigerator. е. The temperature in the kitchen will go up very slightly.
Knowledge Booster
Background pattern image
Mechanical Engineering
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
SEE MORE QUESTIONS
Recommended textbooks for you
Text book image
Refrigeration and Air Conditioning Technology (Mi...
Mechanical Engineering
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:Cengage Learning
The Refrigeration Cycle Explained - The Four Major Components; Author: HVAC Know It All;https://www.youtube.com/watch?v=zfciSvOZDUY;License: Standard YouTube License, CC-BY