Chapter 7, Problem 7.27PP
If the pump in Problem 7.26 operates with an efficiency of
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
A small centrifugal pump is used to deliver 0.005 m/s of water to level 2 as shown in Fig. 2.
Neglecting the losses, determine the required power input to the pump if its efficiency is equal to
70%.
Level 2
30 m
Pump
Figure 2: Schematic diagram of task 2.
A fuel pump is delivering 60 gal/min of oil with a specific gravity of 0.75. The total head is 45 meters. Find the motor that is capable of handling this pump. Assume the pump efficiency of 72 % and motor efficiency of 80 %
A large container filled with water and uncovered for use in fighting fires in an ethylene production plant. Water from this tank is pumped into the nozzle when needed use. This fire suppression system is designed to be able to transmit 1890 L/min of water at a pressure of 15 bar (relative pressure). If we ignore the difference in height between the water level in the tank and pump, there is no change in diameter of pipe and nozzle, pump efficiency is 70%. Ask how much work (hp) is required to the pump to achieve the desired pressure and flow would like?
Chapter 7 Solutions
Applied Fluid Mechanics (7th Edition)
Ch. 7 - A horizontal pipe carries oil with a specific...Ch. 7 - Water at 40 F is flowing downward through the...Ch. 7 - Find the volume flow rate of water exiting from...Ch. 7 - A long DN 150 Schedule 40 steel pipe discharges...Ch. 7 - Figure 7.14 shows a setup to determine the energy...Ch. 7 - A test setup to determine the energy loss as water...Ch. 7 - The setup shown in Fig. 7.16 is being used to...Ch. 7 - A pump is being used to transfer water from an...Ch. 7 - In Problem 7.815 (Fig. 7.17), if the left-hand...Ch. 7 - A commercially available sump pump is capable of...
Ch. 7 - A submersible deep-well pump delivers 745 gal/h of...Ch. 7 - In a pump test the suction pressure at the pump...Ch. 7 - The pump shown in Fig. 7.19 is delivering...Ch. 7 - The pump in Fig. 7.20 delivers water from the...Ch. 7 - Repeat Problem 7.14, but assume that the level of...Ch. 7 - Figure 7.21 shows a pump delivering 840L/min of...Ch. 7 - Figure 7.22 shows a submersible pump being used to...Ch. 7 - Figure 7.23 shows a small pump in an automatic...Ch. 7 - The water being pumped in the system shown in Fig....Ch. 7 - A manufacturer's rating for a gear pump states...Ch. 7 - The specifications for an automobile fuel pump...Ch. 7 - Figure 7.26 shows the arrangement of a circuit for...Ch. 7 - Calculate the power delivered to the hydraulic...Ch. 7 - Water flows through the turbine shown in Fig....Ch. 7 - Calculate the power delivered by the oil to the...Ch. 7 - What hp must the pump shown in Fig. 7.30 deliver...Ch. 7 - If the pump in Problem 7.26 operates with an...Ch. 7 - The system shown in Fig. 7.31 delivers 600 L/min...Ch. 7 - Kerosene (sg = 0.823 ) flows at 0.060m3/s in the...Ch. 7 - Water at 60 F flows from a large reservoir through...Ch. 7 - Figure 7.34 shows a portion of a fire protection...Ch. 7 - For the conditions of Problem 7.31 and if we...Ch. 7 - In Fig. 7.35 kerosene at 25 F is flowing at 500...Ch. 7 - For the system shown in Fig. 7.35 and analyzed in...Ch. 7 - Compute the power removed from the fluid by the...Ch. 7 - Compute the pressure at point 2 at the pump inlet.Ch. 7 - Compute the pressure at point 3 at the pump...Ch. 7 - Compute the pressure at point 4 at the press...Ch. 7 - Compute the pressure at point 5 at the press...Ch. 7 - Evaluate the suitability of the sizes for the...Ch. 7 - The portable, pressurized fuel can shown in Fig....Ch. 7 - Professor Crocker is building a cabin on a...Ch. 7 - If Professor Crocker's pump, described in Problem...Ch. 7 - The test setup in Fig. 7.39 measures the pressure...Ch. 7 - If the fluid motor in Problem 7.44 has an...Ch. 7 - A village with a need for a simple irrigation...Ch. 7 - As a member of a development team for a new jet...Ch. 7 - A fire truck utilizes its engine to drive a pump...Ch. 7 - A home has a sump pump to handle ground water from...Ch. 7 - In Problem 6.107 an initial calculation was made...Ch. 7 - A creek runs through a certain part of a campus...Ch. 7 - A hot tub is to have 40 outlets that are each 8 mm...Ch. 7 - A large chipper/shredder is to be designed for use...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- For a pumper truck pumping water to a fire, the back pressure is the additional pressure on the pump caused by the height of the nozzle. (Another way of thinking of back pressure is as the minimum pressure the pumper must produce in order to make water flow out the end of the nozzle.) Consider a pumper at street level pumping water through a hose to firefighters on the top of the ninth floor of a building. If each floor is 16 feet high, what is the head of water at the mouth of the nozzle?arrow_forward2. A pump draws water from a lake delivered to a height of 50 meters above the lake and encounters 15 meters of headloss. Determine the pump power requirement in Kilo-Watts to deliver a constant supply of 500 Liters per second? The correct answer has a margin of 1 from exact answer. Velocity head is neglected.arrow_forwardA centrifugal pump at peak efficiency operates at 700RPM and provides 30ft head for a flow rate of 100gpm. What will be the flow rate and head at peak efficiency if the pump speed is increased to 2500RPM?arrow_forward
- A pump is driven at 1800 RPM and delivers 12 GPM at 2000 psi. If the volumetric efficiency is 90%, Calculate the volumetric displacement of this pump.arrow_forwardWater recirculates at a volume flow rate of 0.4524 ft3/min from the blade outlet to the impeller, and shaft sealing losses are negligible. A centrifugal pump has a hydraulic efficiency of 95% and a mechanical efficiency of 93%, respectively. Calculate the pump efficiency in percent if the pump delivers water at a flow rate of 12 ft3/min.arrow_forwardThe pump shown is 75% efficient. If the pressure rise is 120 psi, calculate the required energy input in horsepower.arrow_forward
- 4. A submersible pump delivers 350 gpm of water to a height of 5 ft from the ground. The pump was installed 120 ft below the ground level and a draw down of 8 ft during the operation. If water level is 25 ft above the pump, determine the pump power.arrow_forwardWhat is the power ratio of a pump to its 1/5 scale model if the ratio of the heads is 4 to 1?arrow_forwardA submersible pump deliver 350 gpm of water to a height of 5ft from the ground. the pump was installed 120 ft. below the ground level and a draw down of 8 ft. during the operation, if water level is 25 ft. above the pump, determine the pump powerarrow_forward
- An 18-in-diameter centrifugal pump, running at 880 r/min with water at 20°C, generates the following performance data: Plot the required input power versus the flow rate.arrow_forwardWater at 90°C is to be pumped from a low-elevation reservoir to a high-elevation reservoir at a flow rate of 0.0046 cu. meter per second, as shown in the figure below. The atmospheric pressure at the location of the pump installation is 98.4 kPa. The 40-mm-diameter suction pipe has a total length of 7.2 m. The friction factor for the suction pipe is estimated to be 0.025. The centrifugal pump that will be used has an NPSHR of 4.5 m. Will cavitation occur in this pump setup? 5 m ↓ (A) Yes, cavitation will occur with NPSHA equal to 4.80 m. B) Yes, cavitation will occur with NPSHA equal to -5.20 m. No, cavitation will not occur with NPSHA equal to 4.80 m. (D) No, cavitation will not occur with NPSHA equal to -5.20 m. (pump centerline) 19 marrow_forwardIn order to meet the stated goal of delivering 4 gallons per minute at a height of 670 meters, a single pump must have a maximum flow rate of 40 gpm. How many stages are needed if the speed cannot exceed 1352 rpm?arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Elements Of ElectromagneticsMechanical EngineeringISBN:9780190698614Author:Sadiku, Matthew N. O.Publisher:Oxford University PressMechanics of Materials (10th Edition)Mechanical EngineeringISBN:9780134319650Author:Russell C. HibbelerPublisher:PEARSONThermodynamics: An Engineering ApproachMechanical EngineeringISBN:9781259822674Author:Yunus A. Cengel Dr., Michael A. BolesPublisher:McGraw-Hill Education
- Control Systems EngineeringMechanical EngineeringISBN:9781118170519Author:Norman S. NisePublisher:WILEYMechanics of Materials (MindTap Course List)Mechanical EngineeringISBN:9781337093347Author:Barry J. Goodno, James M. GerePublisher:Cengage LearningEngineering Mechanics: StaticsMechanical EngineeringISBN:9781118807330Author:James L. Meriam, L. G. Kraige, J. N. BoltonPublisher:WILEY
Elements Of Electromagnetics
Mechanical Engineering
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Oxford University Press
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:9780134319650
Author:Russell C. Hibbeler
Publisher:PEARSON
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:9781259822674
Author:Yunus A. Cengel Dr., Michael A. Boles
Publisher:McGraw-Hill Education
Control Systems Engineering
Mechanical Engineering
ISBN:9781118170519
Author:Norman S. Nise
Publisher:WILEY
Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:9781337093347
Author:Barry J. Goodno, James M. Gere
Publisher:Cengage Learning
Engineering Mechanics: Statics
Mechanical Engineering
ISBN:9781118807330
Author:James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:WILEY
Fluid Mechanics - Viscosity and Shear Strain Rate in 9 Minutes!; Author: Less Boring Lectures;https://www.youtube.com/watch?v=_0aaRDAdPTY;License: Standard youtube license