Applied Fluid Mechanics (7th Edition)
7th Edition
ISBN: 9780132558921
Author: Robert L. Mott, Joseph A. Untener
Publisher: PEARSON
expand_more
expand_more
format_list_bulleted
Concept explainers
Textbook Question
Chapter 7, Problem 7.46PP
A village with a need for a simple irrigation system proposes to have a collection pool for rain water and then a simple human-powered pump mounted to a stationary bicycle frame to deliver the water to crops during dry times. If the required lift is
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
A right cylindrical container 4 m. diameter is 3 m tall. A 50 mm diameter hole is provided at the bottom of the container to drain the water when necessary. If it is full of water, how long in hours does it take to empty the container from the instant the hole is opened? Coefficient of velocity and coefficient of contraction are both equal to 1.0. A.1.39 hoursC.1.13hoursB.1.26 hoursD.1.49hours
A pump rated at 65% efficiency is used to transport water from a large open reservoir to a point 10m above at a rate of 450 L/min, into a vented tank. Assuming friction is negligible and that the efficiency of the motor is 77%, how much electricity is required to keep the process running for 24 hours?
Choices:
A. 29.37 kWh
B. 35.28 kWh
C. 56.71 kWh
D. 43.21 kWh
2.
A pump draws water from a lake delivered to a height of 50 meters above the lake and encounters 15 meters of headloss. Determine the pump power requirement in Kilo-Watts to deliver a constant supply of 500 Liters per second?
The correct answer has a margin of 1 from exact answer. Velocity head is neglected.
Chapter 7 Solutions
Applied Fluid Mechanics (7th Edition)
Ch. 7 - A horizontal pipe carries oil with a specific...Ch. 7 - Water at 40 F is flowing downward through the...Ch. 7 - Find the volume flow rate of water exiting from...Ch. 7 - A long DN 150 Schedule 40 steel pipe discharges...Ch. 7 - Figure 7.14 shows a setup to determine the energy...Ch. 7 - A test setup to determine the energy loss as water...Ch. 7 - The setup shown in Fig. 7.16 is being used to...Ch. 7 - A pump is being used to transfer water from an...Ch. 7 - In Problem 7.815 (Fig. 7.17), if the left-hand...Ch. 7 - A commercially available sump pump is capable of...
Ch. 7 - A submersible deep-well pump delivers 745 gal/h of...Ch. 7 - In a pump test the suction pressure at the pump...Ch. 7 - The pump shown in Fig. 7.19 is delivering...Ch. 7 - The pump in Fig. 7.20 delivers water from the...Ch. 7 - Repeat Problem 7.14, but assume that the level of...Ch. 7 - Figure 7.21 shows a pump delivering 840L/min of...Ch. 7 - Figure 7.22 shows a submersible pump being used to...Ch. 7 - Figure 7.23 shows a small pump in an automatic...Ch. 7 - The water being pumped in the system shown in Fig....Ch. 7 - A manufacturer's rating for a gear pump states...Ch. 7 - The specifications for an automobile fuel pump...Ch. 7 - Figure 7.26 shows the arrangement of a circuit for...Ch. 7 - Calculate the power delivered to the hydraulic...Ch. 7 - Water flows through the turbine shown in Fig....Ch. 7 - Calculate the power delivered by the oil to the...Ch. 7 - What hp must the pump shown in Fig. 7.30 deliver...Ch. 7 - If the pump in Problem 7.26 operates with an...Ch. 7 - The system shown in Fig. 7.31 delivers 600 L/min...Ch. 7 - Kerosene (sg = 0.823 ) flows at 0.060m3/s in the...Ch. 7 - Water at 60 F flows from a large reservoir through...Ch. 7 - Figure 7.34 shows a portion of a fire protection...Ch. 7 - For the conditions of Problem 7.31 and if we...Ch. 7 - In Fig. 7.35 kerosene at 25 F is flowing at 500...Ch. 7 - For the system shown in Fig. 7.35 and analyzed in...Ch. 7 - Compute the power removed from the fluid by the...Ch. 7 - Compute the pressure at point 2 at the pump inlet.Ch. 7 - Compute the pressure at point 3 at the pump...Ch. 7 - Compute the pressure at point 4 at the press...Ch. 7 - Compute the pressure at point 5 at the press...Ch. 7 - Evaluate the suitability of the sizes for the...Ch. 7 - The portable, pressurized fuel can shown in Fig....Ch. 7 - Professor Crocker is building a cabin on a...Ch. 7 - If Professor Crocker's pump, described in Problem...Ch. 7 - The test setup in Fig. 7.39 measures the pressure...Ch. 7 - If the fluid motor in Problem 7.44 has an...Ch. 7 - A village with a need for a simple irrigation...Ch. 7 - As a member of a development team for a new jet...Ch. 7 - A fire truck utilizes its engine to drive a pump...Ch. 7 - A home has a sump pump to handle ground water from...Ch. 7 - In Problem 6.107 an initial calculation was made...Ch. 7 - A creek runs through a certain part of a campus...Ch. 7 - A hot tub is to have 40 outlets that are each 8 mm...Ch. 7 - A large chipper/shredder is to be designed for use...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- A fuel pump is delivering 50 gals/min of oil with a specific gravity of 0.75. The total head is 30 meters. Find the motor that is capable of handling this pump in horsepower. Assume pump efficiency of 70% and motor efficiency of 80%. Select from the available motors provided: 1hp, 1.25hp, 1.5hp, 2 hp.arrow_forwardA fountain and a water tank will be powered by water from a nearby lake. The elevations and pipe connections are depicted in the diagram below. The fountain's jet water should reach a height of at least 2.5 m from the nozzle outlet. The tank, on the other hand, is elevated to allow gravity to distribute water. The table below contains the specifications for nozzles, suction and discharge pipes. What is the minimum power input to the pump in kW, assuming negligible minor head losses? Assume that the pump efficiency is 88 percent and the motor efficiency is 95 percent. The fountain's water is returned to the lake via a drainage system.arrow_forwardA 20-KW motor with 80% efficiency drives a centrifugal pump delivery 0.08m3/sec against a head of 20m. Determine the pump efficiencyarrow_forward
- A centrifugal pump is driven by a motor. The performance of the pump reveals the folowing information: Power input to the pump by the motor (kW): 0.5, 0.7, 0.9, 1.0, 1.2 Power input to the fluid by the pump (kW): 0.3, 0.55, 0.7, 0.9, 1.0 Plot the efficiency curve. The efficiency of a pump is a function of the flow rate. Assume that the flow-readings corresponding to to power data points are equally spaced.arrow_forward1.) A Pelton wheel with a needle-controlled nozzle develops 1 050 kW against a gross head of 300 m. The loss of head due to friction in the pipeline and the nozzle is 60 xV. where is the flow rate in m³/s. Assuming that the overall efficiency of the wheel remains constant at 83%, determine the percentage reduction in flow rate required when the power developed is reduced to 710 kW by closing a valve on the pipeline partially.arrow_forwardSketch and discuss in great detail the different pump curves including supply curve, system curve and efficiency curve.arrow_forward
- In oasis Water Company to purify the water, it is flowing through a reducer in a horizontal pipe where the diameter is reduced from 35 cm to 25 cm. The pressure in the 35 cm pipe just upstream of the reducer is 3 150 kPa. The fluid has a vapor pressure of 50 kPa and a specific weight of 5 kN/m . Neglecting frictional effects, calculate flow rate of water through this pipe in lit/s. Draw diagram neatly.arrow_forwardWhen two similar pumps operates in parallel, the volumetric capacity of the system changes by a factor of ?arrow_forwardA single pump and system have characteristics as shown on the graph below. Based on this information, estimate: (a) The flow rate with one pump online. (b) The flow rate if the pump's speed is doubled (c) The flow rate of two identical pumps operating in parallel (original pump speeds) (d) The flow rate of two identical pumps operating in series (original pump speed) (e) The flow rate if the system's static head doubles (f) Pump head (original system) if a valve is opened until the flow rate is 5.5 cfs 350 300 250 200 150 100 50 2 4 6. 8 10 12 Flow Rate (cfs) ·hp(req) •hp(avai) Head (ft)arrow_forward
- A pump sends a substance (sg=1.9) from a tank to a tank placed at a higher level, where the velocity is 1 m/s. Considering that the friction losses in the system are 5.8 m and the efficiency of the pump is 68%, find the nominal power of the pump and the pressure developed by it. D4= 6cm D5= 8cm H3= 12marrow_forwardA centrifugal pump driven by a 120-kW motor rotating at 2400 rpm is used to pump 20°C water in a manufacturing plant. The pump operates against a head of 30m and has an efficiency of 70%. What quantity of water (in m^3/s) can the pump deliver?arrow_forward...Determine the power generated in MW by the hydroelectric plant with the following given: Head water level: 120 m Tail water level: 46 m Head loss: 4 m Flowrate: 66 m^3/s Evaporation losses: 16 % Generation Efficiency: 94 % Use two decimal places in the final answer.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Elements Of ElectromagneticsMechanical EngineeringISBN:9780190698614Author:Sadiku, Matthew N. O.Publisher:Oxford University PressMechanics of Materials (10th Edition)Mechanical EngineeringISBN:9780134319650Author:Russell C. HibbelerPublisher:PEARSONThermodynamics: An Engineering ApproachMechanical EngineeringISBN:9781259822674Author:Yunus A. Cengel Dr., Michael A. BolesPublisher:McGraw-Hill Education
- Control Systems EngineeringMechanical EngineeringISBN:9781118170519Author:Norman S. NisePublisher:WILEYMechanics of Materials (MindTap Course List)Mechanical EngineeringISBN:9781337093347Author:Barry J. Goodno, James M. GerePublisher:Cengage LearningEngineering Mechanics: StaticsMechanical EngineeringISBN:9781118807330Author:James L. Meriam, L. G. Kraige, J. N. BoltonPublisher:WILEY
Elements Of Electromagnetics
Mechanical Engineering
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Oxford University Press
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:9780134319650
Author:Russell C. Hibbeler
Publisher:PEARSON
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:9781259822674
Author:Yunus A. Cengel Dr., Michael A. Boles
Publisher:McGraw-Hill Education
Control Systems Engineering
Mechanical Engineering
ISBN:9781118170519
Author:Norman S. Nise
Publisher:WILEY
Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:9781337093347
Author:Barry J. Goodno, James M. Gere
Publisher:Cengage Learning
Engineering Mechanics: Statics
Mechanical Engineering
ISBN:9781118807330
Author:James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:WILEY
Fluid Mechanics - Viscosity and Shear Strain Rate in 9 Minutes!; Author: Less Boring Lectures;https://www.youtube.com/watch?v=_0aaRDAdPTY;License: Standard youtube license